ZONCN 10KV, 2000KW Medium Voltage drive for Aluminum plant crusher Project.
- Technical Features:
- This solution uses a 2000KW inverter to drive a 1600KW motor, with a quick-break protection current of up to 200%, a light-load current of 120% for 60S, and a heavy-load current of 150% for 10S.
- A special algorithm is designed based on the large current fluctuation characteristics of the crusher. When the inverter reaches the quick-break current, the inverter stops outputting. By using the large working inertia of the crusher, it passes the current quick-break zone and tracks the speed to restart. Reduce downtime and improve production efficiency.
- The crusher has large load fluctuations. The comprehensive power saving rate of using the inverter compared to the traditional water resistance cabinet is as high as 55% or more (data source: users use it for half a year and compare it with the water resistance cabinet with the same output)